SY-261D Petroleum Instrument of Fully Automatic Closed Flash Point Tester Information for ordersNameModelTechnical FeaturesStandardsApplicate RangeFully-automatic Pensky-martens Closed Cup Flash Point TesterSY-261DFully-automaticGB/T261-2008ISO2719ASTM D93It is suitable to determine the flash point ......
| Name | Model | Technical Features | Standards | Applicate Range |
| Fully-automatic Pensky-martens Closed Cup Flash Point Tester | SY-261D | Fully-automatic | GB/T261-2008 ISO2719 ASTM D93 | It is suitable to determine the flash point of petroleum products, and with flash points above 40ºC and below 300ºC. |
| Automatic Pensky-martens Closed Cup Flash Point Tester | SY-261A | Fully-automatic | Ditto | Ditto |
| Closed Cup Flash Point Tester | SY-261-1 | Programmed temperature control, LCD display and A&B process | Ditto | Ditto |
| SY-261 | Manual | Ditto | Ditto | |
| Rapid Low Temperature Closed Cup Flash Point Tester | SY-5208 | Automatic finished except manual ignition | GB/T 5208-2008 ISO 1523 ISO 3679 | It is special for the less samples determination, such as colored paint,paint,adhesive,solvent,petroleum and other relevant products which flash point is -30ºC~50ºC. |
| SY-5208D | Automatic finished except manual ignition | GB/T 5208-2008 ISO 1523 ISO 3679 | It is special for the less samples determination, such as colored paint,paint,adhesive,solvent,petroleum and other relevant products which flash point is 0ºC~100ºC. |
| Model | SY-261 | SY-261-1 | SY-261A | SY-261D | SY-5208 | SY-5208D |
| Standard | GB/T261 | GB/T261 | GB/T261 | GB/T261 | GB/T5208 | GB/T5208 |
| Range | (40~300)ºC | (40~300)ºC | (40~300)ºC | (40~300)ºC | (-30~50)ºC | (0~100)ºC |
| Repeatability | 2ºC(≤104ºC) 6ºC(>104ºC) | 2ºC(≤104ºC) 6ºC(>104ºC) | Flash point ≤104ºC:error2ºC; Flash point>104ºC:error6ºC; | 2ºC(≤104ºC) 6ºC(>104ºC) | Absolute difference between two experimental results<2ºC(Same operator) <3ºC(Different operators) | |
| Reproducibility | 4ºC(≤104ºC) 8ºC(>104ºC) | 4ºC(≤104ºC) 8ºC(>104ºC) | Flash point ≤104ºC:error4ºC; Flash point>104ºC:error8ºC; | 4ºC(≤104ºC) 8ºC(>104ºC) | ||
| Automatic up/down | No | No | Yes | Yes | No | No |
| With microprinter | No | No | Yes | Yes | Yes | Yes |
| Display | No | Digital display | Yes | Yes | Yes | Yes |
| Communication port | No | No | No | Yes | No | No |
| Sample | Standard oil cup | Standard oil cup | Standard oil cup | Standard oil cup | 2mL | 2mL |
| Automatic detect | No | Automatic heating up | Yes | Yes | Yes | Yes |
| Power Supply | AC(220±10%)V,50Hz; |
| Test Range | (40~300)ºC; |
| Stirring rate | a.Process A:(90~120)RPM b. Process B:(240~260)RPM |
| Igniting mode | gas flame,electric ignition. |
| Test condition | ambient temperature:(10~40)ºC |
| Total power consumption | ≤500W |




PV Module Flame Test Equipment, UL 1703 , UL 790, IEC 61730
UL 1703 -2004 Falling Ball Impact Tester for PV Module
Solar Panels Testing Hail Impact Testing Machine IEC61646 IEC61215 Standard
Salt Spray Flowing Mixed Gas Corrosion Testing Machine
UL 1703 -2004 Standard Drop Ball Testing Machine
UL 1703 -2004 PV Module Durable Hot Spot Testing Machine